QPHY-PCIE (Gen 1 and 2)
Operators Manual
Revision A March, 2014
Relating to the following release versions:
Software Version Rev. 7.3.0.0
Script
PCI_Express_Test_Spec_Electrical_Layer_3_0_rev_0_9
Style Sheet Rev. 1.2
Vista de pagina 0
1 2 3 4 5 6 ... 29 30

Indice de contenidos

Pagina 1 - Revision A – March, 2014

QPHY-PCIE (Gen 1 and 2) Operator’s Manual Revision A – March, 2014 Relating to the following release versions: Software Version Rev. 7.3.0.

Pagina 2

Installation and Setup QualiPHY is a Windows-based application that can be configured with one or more serial data compliance components. Each comp

Pagina 3 - Table of Contents

QPHY-PCIE Operator’s Manual Set Up Dual Monitor Display Teledyne LeCroy recommends running QualiPHY on an oscilloscope equipped with Dual Monitor Dis

Pagina 4 - About This Manual

Using QualiPHY This section provides an overview of the QualiPHY user interface and general procedures, using examples from the QPHY-BroadR-Reach

Pagina 5 - Introduction

QPHY-PCIE Operator’s Manual General Setup The first sub-dialog contains general system settings. These remain in effect for each session, regardless

Pagina 6 - Test Fixtures

QualiPHY Test Process Once general system settings are in place, these are the steps for running test sessions. Set Up Test Session 1. Connect the

Pagina 7

QPHY-PCIE Operator’s Manual Run Reports The QualiPHY software automates report generation. On the framework dialog, go to General Setup > Report t

Pagina 8

Customizing QualiPHY The pre-loaded configurations cannot be modified. However, you can create your own test configurations by copying one of the p

Pagina 9

QPHY-PCIE Operator’s Manual Edit Variables The Variable Setup tab contains a list of test variables. See QPHY-PCIE Variables for a description of eac

Pagina 10 - Installation and Setup

Edit Test Limits The Limits tab shows the Limit Set currently associated with the configuration. Any limit set can be associated with a custom conf

Pagina 11 - Set Up Remote Control

QPHY-PCIE Operator’s Manual X-Replay Mode The X-Replay mode window is an advanced (“developer”) view of QualiPHY. The tree in the upper-left frame en

Pagina 12 - Using QualiPHY

700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 425-2000, Fax: (845) 578 5985 teledynelecroy.com © 2014 Teledyne LeCroy, Inc.

Pagina 13 - General Setup

QPHY-PCIE Testing Test Preparation Before beginning any test or data acquisition, warm the oscilloscope for at least 20 minutes. Calibration is aut

Pagina 14 - QualiPHY Test Process

QPHY-PCIE Operator’s Manual Variations exist for different source configurations: differential inputs on Input A or Input B, and single inputs on Inp

Pagina 15 - Run Reports

5.0 GT/s Signal Quality Tests The following tests are run on the 5.0GT/s compliance pattern with 3.5dB of de-emphasis and also with 6.0dB of de-emp

Pagina 16 - Customizing QualiPHY

QPHY-PCIE Operator’s Manual QPHY-PCIE Variables CLEAN CLOCK This variable allows the user to select whether or not they are using a clean clock. This

Pagina 17 - Edit Variables

QPHY-PCIE Limit Sets The default installation of QPHY-PCIE contains only one limit set, called PCIe 2.1 This set contains all of the limits for PCI

Pagina 18 - Edit Test Limits

QPHY-PCIE Operator’s Manual • Trigger i.Configure to Source to be FastEdge. ii.Set the Slope to Positive. • Parameter Measurements: i. Set the sou

Pagina 19 - X-Replay Mode

10. Save Channel X to M1. • Click File  Save Waveform. • Set Save To Memory. • Set the Source to CX. • Set the Destination to M1. • Click Sav

Pagina 20 - QPHY-PCIE Testing

QPHY-PCIE Operator’s Manual Cable Deskewing Without Using the Fast Edge Output The following procedure demonstrates how to manually deskew two oscill

Pagina 21 - QPHY-PCIE Test Descriptions

In the previous procedure, we used the default setup of the Skew parameter (which is detecting positive edges on both signals at 50%). We also inve

Pagina 22

QPHY-PCIE Operator’s Manual Error Messages These messages may appear when using QualiPHY. “Warning, no valid technology package has been found…” This

Pagina 23 - QPHY-PCIE Variables

QPHY-PCIE Operator’s Manual Table of Contents Introduction ...

Pagina 25 - QPHY-PCIE Operator’s Manual

Table of Figures Figure 1. Compliance Load Board for 1, 4, 8 and 16 lane connectors (CLB1). ... 2 Figure 2. Comp

Pagina 26

QPHY-PCIE Operator’s Manual Introduction About QualiPHY QualiPHY is a highly automated compliance test software meant to help you develop and validat

Pagina 27

Test Fixtures The PCI Express standard describes a set of two fixtures used for connection to the signal under test: the compliance load board (CLB

Pagina 28

QPHY-PCIE Operator’s Manual The compliance base board (CBB1) provides probing access for 1, 4, 8 and 16 lane connectors that connect to Gen 1.1 add-i

Pagina 29 - Error Messages

The compliance load board (x4/x8 CLB2) provides probing access for 4 and 8 lane connectors that connect to Gen 2.0 system boards. Figure 4. Compli

Pagina 30

QPHY-PCIE Operator’s Manual Required Host Computer System Usually, the oscilloscope is the host computer for the QualiPHY software, and all models t

Comentarios a estos manuales

Sin comentarios