LeCroy Corporation Automation API for SAS/SATATracer/Trainer Manual Version 1.11
37
4.1.8 ITrace::GetPacket
HRESULT GetPacket (
[in] long packet_number,
[in, out] VARIANT* packet,
[out, retval] long* number_of_bits );
Retrieves a raw packet representation in the PACKETFORMAT_BYTES format
(see IPacket Interface
for details).
Parameters
packet_number Zero based number of packet to retrieve
packet
Raw packet representation
number_of_bits
Number of bits in the raw packet representation
Return values
ANALYZERCOMERROR_INVALIDPACKETNUMBER -
specified packet number is invalid
Remarks
The packet parameter has VT_ARRAY | VT_VARIANT actual automation type. Each element of
this array has the
VT_UI1 automation type.
Example
VBScript:
<OBJECT
ID = Analyzer
CLASSID = "clsid: 297CD804-08F5-4A4F-B3BA-779B2654B27C" >
</OBJECT>
<INPUT TYPE=TEXT NAME="TextPacketNumber">
<P ALIGN=LEFT ID=StatusText></P>
<SCRIPT LANGUAGE="VBScript">
<!--
Function DecToBin(Param, NeedLen)
While Param > 0
Param = Param/2
If Param - Int(Param) > 0 Then
Res = CStr(1) + Res
Else
Res = CStr(0) + Res
End If
Param = Int(Param)
Wend
DecToBin = Replace( Space(NeedLen - Len(Res)), " ", "0") & Res
End Function