LeCroy Corporation Verification Script Engine Manual, version 2.2
10 Timer Functions
This group of functions covers VSE capability to work with timers, internal routines that repeatedly
measure a timing interval between different events.
10.1 VSE Time Object
A VSE time object presents time intervals in verification scripts. From the point of view of CSL, the
verification script time object is a “list” object of two elements.
[seconds, nanoseconds]
(See the LeCroy Protocol Analyzers File-Based Decoding User Manual for more details about CSL
types.)
Note: The best way to construct a VSE time object is to use the Time() function (see below).