LeCroy Corporation UWBTrainer Exerciser - Generation Script Language Reference Manual
46
9.6.1.1 Additional Rx Frame Header+Payload Condition parameters
You can specify additional matching parameters inside the Register Rx Frame Header +Payload
Condition Instruction block that are not part of the PHY-MAC header and frame payload. Such
parameters include RSSI, LQI, Frame duration ranges, and errors.
Format:
RxFrameInfo
{
Parameter 1
Parameter N
}
The format of additional condition parameters is defined by the RxFrameInfo structure (defined in
the Generation\Include\ RxFrameInfo.ginc file):
struct RxFrameInfo
{
RSSI_Lo : 8 # RSSI lower limit
RSSI_Hi : 8 # RSSI upper limit
LQI_Lo : 8 # LQI lower limit
LQI_Hi : 8 # LQI upper limit
Duration_Lo : 32 # Frame duration lower limit in microseconds
Duration_Hi : 32 # Frame duration upper limit in microseconds
Reserved_0 : 8 # reserved value, should not be used
Errors # error flags
{
Reserved_1 : 2
FrmAborted : 1 # Frame Aborted error flag
FCSError : 1 # FCS error flag
LenError : 1 # Frame Length error flag
HdrError : 1 # Frame Header error flag
PldError : 1 # Frame Payload error flag
UnsptdRate : 1 # Unsupported Rate error flag
}
}