Figure 23 - Oscilloscope Configuration after the Rj and Tj Tests
Shown on this screen:
F1 is the differential input waveform.
RjBUjHist is the histogram of the random and bounded uncorrelated jitter. This is the same as the
full TIE histogram with the DDj removed. The RjBUjHist is an output from SDA III.
To comply with the JTF requirements when SSC is not enabled a single-pole PLL is used in SDA III and
when SSC is enabled a two-pole PLL is used. The PLLs have the following characteristics:
Without SSC Support
With SSC Support
Pole Frequency
Natural Frequency
1.5Gbps
1.7MHz
2.1MHz
3Gbps
3.2MHz
3.0MHz
6Gbps
5.6MHz
4.2MHz
12Gbps
5.5MHz
4.2 MHz
Note: For more information on SDA III refer to the Understanding SDA III Jitter Calculation Methods technical brief
available at the following address:
http://www.teledynelecroy.com/files/WhitePapers/Understanding_SDAIII_Jitter_Calculation_Methods.pdf