RxCmd1 Right-Hand Dialog - Provide values for the RT and Sub Address fields complete with Condition,
Value, To (for range conditions), and T/R controls. Word Count/Mode Code fields include Condition and
Mode Code controls. Select from 32 possible Mode Code values:
Override
Transmitter
Shutdown
Override Inhibit
Terminal Flag
Selected
Transmitter
Shutdown
Override Selected
Transmitter
Shutdown
DW Right-Hand Dialog - Provide Data Pattern Setup field values for Data Condition,Start Bit and # Data
Bits, Data Value and Data Value To (for range conditions).
WORD SUB-TYPES, SETUP FORMAT, AND RIGHT-HAND DIALOGS
4. Setup Format
Note: When Transfer and Word Types are selected, the Setup Format section is shown in the area on label 4
of the screen-shot in the MIL-STD-1553 Trigger Setup Detail (on page 107) topic.
Select from either Binary or Hexadecimal (Hex) formats for your values entered on sub-type right-hand dialogs.
When the Word Type is selected on the Trigger Condition dialog, the All, Command, Data, and Status sub-types
are available.
5. Word Sub-Type Right-Hand Dialogs
When any sub-types other than All is selected, a correspondingly named right-hand dialog is shown.
Note: Right-hand dialogs are located in the area shown on label 5 of the screen-shot in the MIL-STD-1553
Trigger Setup Detail (on page 107) topic.
Command Sub-Type and Right-Hand Dialog
When the Command sub-type is selected, the Command right-hand dialog is made available. Provide values for
the RT and Sub Address fields complete with Condition, Value, To (for range conditions), and T/R controls.
Word Count/Mode Code fields include Condition and Word Count (amount) controls.
Data Sub-Type and Right-Hand Dialog
When the Data sub-type is selected, the Data right-hand dialog is made available. Provide Data Pattern Setup
field values for Data Condition,Start Bit and # Data Bits, Data Value and Data Value To (for range conditions).