Serial Data Debug Solutions
BRIEF HS COMMON MODE TEST DESCRIPTIONS
With HS Common Mode selected in the Category field, the following Measure values are available:
VCMTX-DATA-1, VCMTX-DATA-0, VCMTX-CLK-1, VCMTX-CLK-0, dVCMTXLF-DATA, dVCMTXHF-DATA,
dVCMTXLF-CLK, and dVCMTXHF-CLK.
To verify that the Static Common-Mode Voltages (VCMTX(1), and VCMTX(0)) of the DUT Data &
Clock Lanes HS transmitter are within the conformance limits.
To verify that the AC Common-Mode Signal Level Variations between 50 and 450MHz
(ΔVCMTX(LF)) of the DUT Data & Clock Lanes HS transmitter are less than the maximum
allowable limit.
To verify that the AC Common-Mode Signal Level Variations above 450MHz (ΔVCMTX(HF)) of the
DUT Data & Clock Lanes HS transmitter are less than the maximum allowable limit.
BRIEF HS LEVELS TEST DESCRIPTIONS
With HS Levels selected in the Category field, the following Measure values are available:
VOD-DATA-1, VOD-DATA-0, VOD-CLK-1, VOD-CLK-0, VOHHS-Dp, VOHHS-Dn, VOHHS-CLKp, and VOHHS-
CLKn.
To verify that the Differential Voltages (VOD(0) and VOD(1)) of the DUT Data & Clock
Lanes HS transmitter are within the conformance limits.
To verify that the Single-Ended Output High Voltages (VOHHS(DP) and VOHHS(DN)) of the
DUT Data & Clock Lanes HS transmitter are less than the maximum conformance limit.