Instructions918246‐00‐RevA1Introduction ThankyouforpurchasingaLeCroyZiOscilloscopeSynchronizationProBusModule(Zi‐8CH‐SYNCHmodule).T
ZiOscilloscopeSynchronizationModule10918246‐00‐RevA2. Connectone36"SMAcabletotheSMApowersplitter(provided)andtowhateverfaste
Instructions918246‐00‐RevA11Thehighlightedsectionofthefollowingfigureillustratesthisuseofthemodule.Tip:TurningonWaveStreamorpers
ZiOscilloscopeSynchronizationModule12918246‐00‐RevA5. UponcompletionofeitherUserEdge orPeriodicdeskewadjustments;theMasterandSlave
Instructions918246‐00‐RevA13Now,aligntheedgesofyouracquiredsignalsbyfineadjustingthedeskewvalueoftheC2(Master)channel(theonepr
ZiOscilloscopeSynchronizationModule14918246‐00‐RevAZi Oscilloscope Synchronization Module Part Reference Tables Usethefollowingparttablesfor
Instructions918246‐00‐RevA15 LeCroyCorporation700ChestnutRidgeRoadChestnutRidge,NY,10977‐6499Tel:(845)578‐6020,Fax:(845)5785985W
ZiOscilloscopeSynchronizationModule16918246‐00‐RevAOperating Environment BeforeusingyourLeCroyaccessory,ensureitsoperatingenvironmentwil
ZiOscilloscopeSynchronizationModule2918246‐00‐RevATheuserinterfaceforcommontriggeringanddisplayofchannelsisenabledontheMasteroscil
Instructions918246‐00‐RevA3Synchronized Periodic Trigger Intheabsenceofanexternalcustomerinputsignal(TRIG‐IN),theZi‐8CH‐SYNCHProBusmod
ZiOscilloscopeSynchronizationModule4918246‐00‐RevASignal Connections Withtheaforementionedprerequisiteconfigurationsmade,setyoursystemup
Instructions918246‐00‐RevA56. Now,makesignalinputconnections asdesired.• IfprovidingyourownEdgeTriggerInputsignal,connectittoth
ZiOscilloscopeSynchronizationModule6918246‐00‐RevA2. Providetheslave'sIPaddressortheoscilloscopenameintheIPAddress/RemoteSla
Instructions918246‐00‐RevA7• DisconnectyourZi‐8CH‐SYNCHmodulebyfirstclickingtheDisconnectSlaveDSObuttonontheRemoteSlaveDSOdialog,
ZiOscilloscopeSynchronizationModule8918246‐00‐RevANote:IntheClockSourcedialog,theZi‐8CH‐SYNCHmodulesetstheReferenceClocktoExternal
Instructions918246‐00‐RevA9Deskewing Master and Slave Channels Deskew Theory of Operation Deskewingisanadjustmentofwaveformdatapointoccurre