LeCroy Corporation Exercise and Capture
146
Sierra M64 SAS/SATA Protocol Analyzer User Manual
Choose Host Emulator Port
For each port, select a speed.
Pattern Generator
You can select a Pattern Generation file. To perform a capture with a Pattern Generator,
enter a path to a pattern generator *.spg file in the File Name dialog. See “Creating a
Pattern Generator File” on page 449 for instructions how to create a Pattern Generator
file.
Host Emulator
You can run an Host Emulator while setting:
Auto stop exerciser when Analyzer stops
CONT usage
Delay between getting HOLD to Sending HOLDA
Data Frame Payload Size
ATA Command Execution Timeout
Logical Block Size (for ATAPI)
Check Autostopex erciserwhenAnalyzerStopped to halt the Host Emulator when the
Analyzer stops.
Check CONTUsageto enable the specification of DelaybetweengettingHOLDto
sendingHOLDA, DataFramePayloadSize, and ATACommandExecutionTimeout.
ATA Command Execution Timeout
The ATA Command Execution Timeout is a timeout for ATA commands. When the host
sends an H2D frame (i.e., it issues a command) and receives an R_OK from the device, it
starts this timer. If the execution of the command takes more than the timeout specified
(15 seconds is the default), the host emulator performs the action specified in the
Advanced/General/ ATA command timeout recovery action settings. The options are
Nothing, Send Soft Reset and Hard Reset.