LeCroy Corporation Scenario Batch Files
366
Sierra M64 SAS/SATA Protocol Analyzer User Manual
Run
Runs the scenario on hardware on specified ports. If you call this command for the first
time and the scenario was not assigned to the hardware and ports before, the scenario is
assigned to specified hardware and ports and then scenario runs on the hardware.
Format
Run(Serial Number, Scenario Name, Target Port)
Parameters
SerialNumber: Serial number of hardware
ScenarioName: Name of scenario
TargetPort: Port number in port map
Example
Run (ox841200," Substitute address frame", 4)
Beep(800, 400)
Run (ox841200," CRC Inject _ Play CD", 8)
WaitForStop(0x63463, 1, 150)
Run (ox841200," Remove Send Cue Sheet", 2)
Goto Label6
Run (S/N: 12871, Port 1, DISCOVER)
Note:If the selected ports are busy, scenario cannot run, and the command will be skipped. The result
will be written in Log area.
Stop
Stops running scenario by hardware and port name.
Format
Stop (Serial Number, Target Port)
Parameters
SerialNumber: Serial number of hardware
TargetPort: Port number in port map
Example
Run (ox00820,"Inject CRC000", 2)
Beep(700, 500)
Stop (ox00820, 2)
Goto Label3
...
Label3 : Run(ox005007,"Detect DATA", 8)
Sleep(40)