 Sierra M64 SAS/SATA Protocol Analyzer User Manual 367
Scenario Batch Files
LeCroy Corporation
WaitForStop
Used to wait for occurrence of specified condition.
Format
WaitForStop(SerialNumber, Target Port, Duration)
Parameters
SerialNumber: Serial number of hardware
TargetPort: Port number in port map
Duration: Integer or random duration in milliseconds. In the Command Parame
ters Window, WaitForStop duration has three options:
Infinite: Wait until Stop command.
Random: Stop after a random time.
Finitetime: Stop after specified time in milliseconds.
Example
Run (ox001267,"Detect AddressFrame Open", 2)
WaitForStop (0x348790, 2, Forever)
Run (ox005007,"Detect DATA", 4)
WaitForStop(ox005007, 4, 100)
Stop (ox001267, 2