LeCroy Corporation Scenario Actions
332
Sierra M64 SAS/SATA Protocol Analyzer User Manual
Using Captured Data DWORDs
Captured data DWORDs can be used in creating events for data that match the captured
DWORD(s), or in creating actions to substitute the captured DWORD(s) into the data
stream.
To create an event using the captured DWORD, in the Event Properties menu, select SAS
DataPattern (or SATADataPattern), and then select any of the 12 DWORDs (DWORD0
Type through DWORD11Type). The dropdown menu provides the choice of a custom
DWORD or any of the four captured DWORDs. If you select a captured DWORD, the Value
field beneath this selection is hidden (the Value field is only used for specifying custom
DWORDs). Note that choice of a mask and an offset are still available when using
captured DWORDs.
Figure 4.22: Using a Captured DWORD in a SAS Data Pattern
Vista de pagina 333