LeCroy Corporation Sierra Trainer Generation Language
422
Sierra M64 SAS/SATA Protocol Analyzer User Manual
SASSpeedNegotiationSettings
OOB_SAS_Align1_Time 81920 ALIGN(1) time for SAS speed negotiation in
OOBIs.During the specified period, the generator will
transmit ALIGN(1) primitives.
OOB_SAS_Align0_Time 81920 ALIGN(0) time for SAS speed negotiation in
OOBIs.During the specified period, the generator will
transmit ALIGN(0) primitives.
OOB_SAS_Interspeed_Time 750000 Interspeed time for SAS speed negotiation in
OOBIs.During the specified period, the generator will
keep the line at electric idle.
OOB_SpeedNeg_MTT. 29998080
OOBI
The maximum time in OOBI during which training
phase of speed negotiation should be completed in
TrainSNW.
OOB_SpeedNeg_SNTT. 2200
OOBI
The time in OOBI during which generator transmits
phy capability bits in SNW3. In Automatic
connection This value is also used for the time during
which generator sends Align0 and Align1 in SNW1
and SNW2.
OOB_SpeedNeg_BCT. 2200
OOBI
The time in OOBI during which generator transmits
COMWAKE or D.C. idle during SNW3.
Setting
Default
Value Description