LeCroy Corporation Target and Device Emulation
180
Sierra M64 SAS/SATA Protocol Analyzer User Manual
Target Emulator Settings (SAS)
Click the Settings tab to display the Target Emulator Settings dialog.
Figure 2.186: SAS: Target Emulator Settings Dialog
The Settings page opens with a default set of values, which you can modify. To return to
these values, click the Defa ultSettings button.
Define the Target
Enter a SASAddress,DataFramePayloadSize,LogicalBlockSize,LinkedCommand
ExpiredTime, and ALIGNTransmissionPeriod in the corresponding text box.
Media Settings
Enter a value for Average Access Time to simulate Seek/Access time delay of a real
device.
Enter a Number of Writable Areas. DefineaStartand an EndAddress,click the down
arrow under theAreaType, and choose NormalWritable,CircularWritable, or Non
Writable.
Note:To set and get the settings of Media Settings Area Types, use these two functions:
SetMediaAreaAttribute(int nAreaIndex, int nStartAddress, int nEndAddress,
TrgEmulMediaAreaTypeEnum eAreaType, int* pnErrorCode)
GetMediaAreaAttribute(int nAreaIndex, int* pnStartAddress,
int* pnEndAddress, TrgEmulMediaAreaTypeEnum* peAreaType)
nAreaIndex: Specifies the (zero base) index of the Area.
Note:The Number of Areas should be set by the SetNumberOfMediaArea function prior to calling
these functions.