LeCroy Corporation Target and Device Emulation
172
Sierra M64 SAS/SATA Protocol Analyzer User Manual
Figure 2.178: Outgoing Frame Setting Dialog
Frame Type Error
Check this to introduce a frame type error.
Remove Frame from sequence
Check this to remove frame from sequence.
Delay in sending frame
Check this to delay sending frame and enter a value for the delay.
Frame Length Error
Check Frame Length Error and choose the type of error to introduce.
Code Violation and Disparity error
Check these and specify DWORD offset and the number of error DWORDs.
Don’t check credit
Check this to disable credit checking.
SOF, EOF, and CRC errors
Check these and specify Double or Omit by checking the corresponding option button.
Insert Primitive
Check Insert Primitive, click the Type button to open the Primitive Type dialog, select the
primitive type, and click OK.
Destroy Field of Frame
Make sure to click the More button and then check the field to destroy.