 Sierra M64 SAS/SATA Protocol Analyzer User Manual 351
Creating a Sequence
LeCroy Corporation
17. You are finished creating the first sequence. Click the addanothersequence prompt
to create an area in the scenario for the second sequence (Sequence 1).
Figure 4.43: Example 7: Adding a Second Sequence
18. Create two states in the second sequence with the characteristics shown in the
following table.
TABLE 4.9: Example 7: States for Second Sequence
State Event Action
0 Address Frame from Target Branch to State 1
1 Address Frame from Initiator Beep for 2 seconds.