Teledyne-lecroy STX M6-1 SAS_SATA Protocol Analyzer User Manual Manual de usuario Pagina 75

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 468
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 74
 Sierra M64 SAS/SATA Protocol Analyzer User Manual 73
Easy Mode (PreDefined Setups)
LeCroy Corporation
The SATA Parameterswindow displays the following trigger pattern categories:
Timer
Timeout
External Trigger
Bus Condition
Symbol
Primitive
FIS
FIS Pattern
ATA Command
ATA Command Pattern
ATAPI
Soft Reset
Data Pattern
Protocol Errors
Note:In packet view, you can rightclick on any frame, select AddtoTrigger, and add the pattern to
DataPatternCapture to make it a trigger pattern.
Choosing a Parameter
Either highlight the category and click the Add>> button, or doubleclick the category, to
open a corresponding definition dialog.
To remove an item, highlight it in the Project Tree, then click the <<Remov e button.
Triggering on a Timer
Selecting a timer for a trigger in the AnyTriggerMode limits the time that the analyzer
looks for selected triggering conditions before triggering. The timer activates when the
Project runs. If none of the selected triggering conditions occurs during the timers active
time, the Analyzer triggers at the end of the time set for the timer.
You can set a timer independently of any other trigger selection, to cause an
unconditional trigger after a set time.
To set the timer value, doubleclick Timer in the Pattern window to open the Timer
dialog.
Figure 2.39: Timer Dialog
Check a Time Unit, enter the Timer Value, and click OK.