 Sierra M64 SAS/SATA Protocol Analyzer User Manual 405
Sierra Trainer Generation Language
LeCroy Corporation
Sierra Trainer Generation Commands
General Commands
IDLE (n) Generator will insert n idle DWORDs into the
generation stream.
CLEAR_CREDIT_AVAIL This commands clears the credit established
with the command WF_CREDIT_AVAIL. (See
WF_CREDIT_AVAIL in following section on Wait
Commands for explanation).
RD_ERROR Generator will insert one idle DWORD into the
generation stream, which will intentionally
break RD sequence creating RD error.
CONNECT Generator will go through connection sequence
using current GenFile settings (gen mode,
speed, and so on). Generation will not resume
until connection is established.
DISCONNECT Generator will break existing connection to DUT.
PAUSE Generator will come to a break and the user will
be able to resume generation by pressing
Resume button on Generation toolbar.
Generator shall transmit idle DWORDs while in
the Pause.
OUTPUT_ON Takes the Trainer out of Electric Idle state. If it is
already out of Electric Idle, this is a NOP.
OOB Commands
COMINIT Generator will send COMINIT OOB signals using
current COMINIT settings.
COMRESET Generator will send COMRESET OOB signals
using current COMRESET settings.
COMWAKE Generator will send COMWAKE OOB signals
using current COMWAKE settings.
COMSAS Generator will send COMSAS OOB signals using
current COMSAS settings.
SATA_ALIGN Generator will go through SATA_ALIGN stage of
SATA SpeedNeg process using current
SATA_ALIGN settings.
SATA_D10_2 Generator will go through SATA_D10_2 stage of
SATA SpeedNeg process using current
SATA_D10_2 settings.
SPEED_NEG_RCDT Generator will go through SPEED_NEG_RCDT
stage of SAS SpeedNeg process using current
SPEED_NEG_RCDT settings.
SPEED_NEG_ALIGN0 Generator will go through SPEED_NEG_ALIGN0
stage of SAS SpeedNeg process using current
SPEED_NEG_ALIGN0 settings.
Vista de pagina 406